Difference between revisions of "Effective dose"

From ICRPaedia
Jump to navigation Jump to search
(Created page with "100px|frameless|right|link=ICRP Glossary the effective dose is calculated as: <math>H_T^M</math> where H_T^M and H_T^F are the equivalent doses...")
 
Line 2: Line 2:
 
the effective dose is calculated as:
 
the effective dose is calculated as:
  
<math>H_T^M</math>
+
where <math>H_T^M</math> and math>H_F^M</math> are the equivalent doses to the tissues or organs <math>r_T</math> of the Reference Adult Male and the Reference Adult Female, respectively and <math>w_T</math> is the tissue weighting factor for target tissue T, with
  
where H_T^M and H_T^F are the equivalent doses to the tissues or organs r_T of the Reference Adult Male and the Reference Adult Female, respectively and w_T is the tissue weighting factor for target tissue T, with ∑_T▒w_T = 1. Effective dose is a weighted average of equivalent doses to organs/tissues. The averaging is performed over all organs and tissues of the human body for which radiation detriment can be quantified and for which wT values are assigned. As w_R and w_T are dimensionless, the SI unit for effective dose is the same as for absorbed dose J kg^(-1) and its special name is sievert (Sv).
+
<math>/sum_limits_T w_T = 1.
 +
 
 +
Effective dose is a weighted average of equivalent doses to organs/tissues. The averaging is performed over all organs and tissues of the human body for which radiation detriment can be quantified and for which wT values are assigned. As w_R and w_T are dimensionless, the SI unit for effective dose is the same as for absorbed dose J kg^(-1) and its special name is sievert (Sv).
  
  

Revision as of 21:41, 28 March 2021

Glossary Icon-2.png

the effective dose is calculated as:

where [math]H_T^M[/math] and math>H_F^M</math> are the equivalent doses to the tissues or organs [math]r_T[/math] of the Reference Adult Male and the Reference Adult Female, respectively and [math]w_T[/math] is the tissue weighting factor for target tissue T, with

<math>/sum_limits_T w_T = 1.

Effective dose is a weighted average of equivalent doses to organs/tissues. The averaging is performed over all organs and tissues of the human body for which radiation detriment can be quantified and for which wT values are assigned. As w_R and w_T are dimensionless, the SI unit for effective dose is the same as for absorbed dose J kg^(-1) and its special name is sievert (Sv).



Return to Glossary

Previous glossary entries

from ICRP Publication 131, 2015

Lorum ipsum...