Difference between revisions of "Effective dose"

From ICRPaedia
Jump to navigation Jump to search
Line 4: Line 4:
 
where <math>H_T^M</math> and math>H_F^M</math> are the equivalent doses to the tissues or organs <math>r_T</math> of the Reference Adult Male and the Reference Adult Female, respectively and <math>w_T</math> is the tissue weighting factor for target tissue T, with  
 
where <math>H_T^M</math> and math>H_F^M</math> are the equivalent doses to the tissues or organs <math>r_T</math> of the Reference Adult Male and the Reference Adult Female, respectively and <math>w_T</math> is the tissue weighting factor for target tissue T, with  
  
<math>/sum_limits_T w_T = 1</math>.
+
<math>\sum\limits_T w_T = 1</math>.
  
 
Effective dose is a weighted average of equivalent doses to organs/tissues. The averaging is performed over all organs and tissues of the human body for which radiation detriment can be quantified and for which <math>w_T</math> values are assigned. As <math>w_R</math> and <math>w_T</math> are dimensionless, the SI unit for effective dose is the same as for absorbed dose <math>J kg^(-1)</math> and its special name is [[sievert]] (Sv).
 
Effective dose is a weighted average of equivalent doses to organs/tissues. The averaging is performed over all organs and tissues of the human body for which radiation detriment can be quantified and for which <math>w_T</math> values are assigned. As <math>w_R</math> and <math>w_T</math> are dimensionless, the SI unit for effective dose is the same as for absorbed dose <math>J kg^(-1)</math> and its special name is [[sievert]] (Sv).

Revision as of 21:43, 28 March 2021

Glossary Icon-2.png

the effective dose is calculated as:

where [math]H_T^M[/math] and math>H_F^M</math> are the equivalent doses to the tissues or organs [math]r_T[/math] of the Reference Adult Male and the Reference Adult Female, respectively and [math]w_T[/math] is the tissue weighting factor for target tissue T, with

[math]\sum\limits_T w_T = 1[/math].

Effective dose is a weighted average of equivalent doses to organs/tissues. The averaging is performed over all organs and tissues of the human body for which radiation detriment can be quantified and for which [math]w_T[/math] values are assigned. As [math]w_R[/math] and [math]w_T[/math] are dimensionless, the SI unit for effective dose is the same as for absorbed dose [math]J kg^(-1)[/math] and its special name is sievert (Sv).



Return to Glossary

Previous glossary entries

from ICRP Publication 131, 2015

Lorum ipsum...