The air kerma on the central x-ray beam axis at the point where the x-ray beam enters the patient. The contribution of backscatter radiation is included through backscatter factor ([math]B[/math]), thus:
[math]K_e= B⋅K_i[/math]
The unit for entrance surface air kerma is the Gy. Entrance surface air kerma [math]K_e[/math] can be calculated from incident air kerma [math]K_i[/math] using suitable backscatter factor [math]B[/math], or determined directly using small dosimeters (thermoluminescent or semiconductor) positioned at the representative point on the skin of the patients. (Adapted from ICRP Publication 117, 2010)