Difference between revisions of "Equivalent dose"
Line 9: | Line 9: | ||
where D<sub>R,T</sub> is the mean absorbed dose from radiation R in a tissue or organ T, and w<sub>R</sub> is the radiation weighting factor. The SI unit of equivalent dose is joule per kilogram (J/kg<sup>-1</sup>), and its special name is sievert (Sv). ([[ICRP Publication 123]], 2013) | where D<sub>R,T</sub> is the mean absorbed dose from radiation R in a tissue or organ T, and w<sub>R</sub> is the radiation weighting factor. The SI unit of equivalent dose is joule per kilogram (J/kg<sup>-1</sup>), and its special name is sievert (Sv). ([[ICRP Publication 123]], 2013) | ||
+ | ''[[ICRP Glossary]] entry - May 2019'' | ||
β | ''[[ICRP Glossary]] | + | |
+ | ===Previous Description=== | ||
+ | The equivalent dose to a tissue or organ is deο¬ned as: | ||
+ | <div style='text-align: center;'> | ||
+ | <math> | ||
+ | H_T = \displaystyle \sum_{R} w_RD_{R,T} | ||
+ | </math> | ||
+ | </div> | ||
+ | where π€π
is the radiation weighting factor for radiation type R, and π·π
,π is the organ absorbed dose from radiation type R in a tissue or organ ππ of the Reference Adult Male or the Reference Adult Female. As π€π
is dimensionless, the SI unit for the equivalent dose is the same as for absorbed dose, J kg-1, and its special name is sievert (Sv). (From [[ICRP Publication 130]], 2015) | ||
+ | |||
+ | The equivalent dose to a tissue or organ is deο¬ned as: | ||
+ | <div style='text-align: center;'> | ||
+ | <math> | ||
+ | H_T = \displaystyle \sum_{R} w_RD_{R,T} | ||
+ | </math> | ||
+ | </div> | ||
+ | where π€π
is the radiation weighting factor for radiation type R, and π·π
,π is the organ absorbed dose from radiation type R in a tissue or organ ππ of the Reference Adult Male or the Reference Adult Female. As π€π
is dimensionless, the SI unit for the equivalent dose is the same as for absorbed dose, joule per kilogram (J kg-1) and its special name is sievert (Sv).(From [[ICRP Publication 133]], 2016) | ||
+ | |||
+ | '''Return to [[ICRP Glossary|Glossary]]''' |
Revision as of 15:44, 12 September 2019
The equivalent dose in an organ or tissue is given by:
[math] H_T = \displaystyle \sum_{R} w_RD_{R,T} [/math]
where DR,T is the mean absorbed dose from radiation R in a tissue or organ T, and wR is the radiation weighting factor. The SI unit of equivalent dose is joule per kilogram (J/kg-1), and its special name is sievert (Sv). (ICRP Publication 123, 2013)
ICRP Glossary entry - May 2019
Previous Description
The equivalent dose to a tissue or organ is deο¬ned as:
[math] H_T = \displaystyle \sum_{R} w_RD_{R,T} [/math]
where π€π is the radiation weighting factor for radiation type R, and π·π ,π is the organ absorbed dose from radiation type R in a tissue or organ ππ of the Reference Adult Male or the Reference Adult Female. As π€π is dimensionless, the SI unit for the equivalent dose is the same as for absorbed dose, J kg-1, and its special name is sievert (Sv). (From ICRP Publication 130, 2015)
The equivalent dose to a tissue or organ is deο¬ned as:
[math] H_T = \displaystyle \sum_{R} w_RD_{R,T} [/math]
where π€π is the radiation weighting factor for radiation type R, and π·π ,π is the organ absorbed dose from radiation type R in a tissue or organ ππ of the Reference Adult Male or the Reference Adult Female. As π€π is dimensionless, the SI unit for the equivalent dose is the same as for absorbed dose, joule per kilogram (J kg-1) and its special name is sievert (Sv).(From ICRP Publication 133, 2016)
Return to Glossary