Difference between revisions of "Equivalent dose"

From ICRPaedia
Jump to navigation Jump to search
(Previous Description)
Line 1: Line 1:
 +
[[File:Glossary Icon-2.png|100px|frameless|right|link=ICRP Glossary]]
 
The equivalent dose in an organ or tissue is given by:
 
The equivalent dose in an organ or tissue is given by:
  
Line 7: Line 8:
 
</div>
 
</div>
  
where D<sub>R,T</sub> is the mean absorbed dose from radiation R in a tissue or organ T, and w<sub>R</sub> is the radiation weighting factor. The SI unit of equivalent dose is joule per kilogram (J/kg<sup>-1</sup>), and its special name is sievert (Sv). ([[ICRP Publication 123]], 2013)
+
where D<sub>R,T</sub> is the mean absorbed dose from radiation R in a tissue or organ T, and w<sub>R</sub> is the radiation weighting factor. The SI unit of equivalent dose is joule per kilogram (J/kg<sup>-1</sup>), and its special name is sievert (Sv).
  
''[[ICRP Glossary]] entry -  May 2019''
+
([[ICRP Publication 123]], 2013)
  
 +
'''Return to [[ICRP Glossary|Glossary]]'''
 +
 +
See also the ICRPaedia entry on [[Absorbed,_Equivalent,_and_Effective_Dose|absorbed, equivalent, and effective dose]].
 +
 +
== Previous glossary entries ==
 +
 +
=== from [[ICRP Publication 130]], 2015 ===
  
===Previous Description===
 
 
The equivalent dose to a tissue or organ is defined as:  
 
The equivalent dose to a tissue or organ is defined as:  
 
<div style='text-align: center;'>
 
<div style='text-align: center;'>
Line 19: Line 26:
 
</math>
 
</math>
 
</div>
 
</div>
where 𝑤𝑅 is the radiation weighting factor for radiation type R, and 𝐷𝑅,𝑇 is the organ absorbed dose from radiation type R in a tissue or organ 𝑟𝑇 of the Reference Adult Male or the Reference Adult Female. As 𝑤𝑅 is dimensionless, the SI unit for the equivalent dose is the same as for absorbed dose, J kg-1, and its special name is sievert (Sv). (From [[ICRP Publication 130]], 2015)
+
where 𝑤𝑅 is the radiation weighting factor for radiation type R, and 𝐷𝑅,𝑇 is the organ absorbed dose from radiation type R in a tissue or organ 𝑟𝑇 of the Reference Adult Male or the Reference Adult Female. As 𝑤𝑅 is dimensionless, the SI unit for the equivalent dose is the same as for absorbed dose, J kg-1, and its special name is sievert (Sv).
  
 +
=== from [[ICRP Publication 133]], 2016 ===
  
 
The equivalent dose to a tissue or organ is defined as:  
 
The equivalent dose to a tissue or organ is defined as:  
Line 28: Line 36:
 
</math>
 
</math>
 
</div>
 
</div>
where 𝑤𝑅 is the radiation weighting factor for radiation type R, and 𝐷𝑅,𝑇 is the organ absorbed dose from radiation type R in a tissue or organ 𝑟𝑇 of the Reference Adult Male or the Reference Adult Female. As 𝑤𝑅 is dimensionless, the SI unit for the equivalent dose is the same as for absorbed dose, joule per kilogram (J kg-1) and its special name is sievert (Sv).(From [[ICRP Publication 133]], 2016)
+
where 𝑤𝑅 is the radiation weighting factor for radiation type R, and 𝐷𝑅,𝑇 is the organ absorbed dose from radiation type R in a tissue or organ 𝑟𝑇 of the Reference Adult Male or the Reference Adult Female. As 𝑤𝑅 is dimensionless, the SI unit for the equivalent dose is the same as for absorbed dose, joule per kilogram (J kg-1) and its special name is sievert (Sv).
 
 
'''Return to [[ICRP Glossary|Glossary]]'''
 

Revision as of 19:25, 12 August 2021

Glossary Icon-2.png

The equivalent dose in an organ or tissue is given by:

[math] H_T = \displaystyle \sum_{R} w_RD_{R,T} [/math]

where DR,T is the mean absorbed dose from radiation R in a tissue or organ T, and wR is the radiation weighting factor. The SI unit of equivalent dose is joule per kilogram (J/kg-1), and its special name is sievert (Sv).

(ICRP Publication 123, 2013)

Return to Glossary

See also the ICRPaedia entry on absorbed, equivalent, and effective dose.

Previous glossary entries

from ICRP Publication 130, 2015

The equivalent dose to a tissue or organ is defined as:

[math] H_T = \displaystyle \sum_{R} w_RD_{R,T} [/math]

where 𝑤𝑅 is the radiation weighting factor for radiation type R, and 𝐷𝑅,𝑇 is the organ absorbed dose from radiation type R in a tissue or organ 𝑟𝑇 of the Reference Adult Male or the Reference Adult Female. As 𝑤𝑅 is dimensionless, the SI unit for the equivalent dose is the same as for absorbed dose, J kg-1, and its special name is sievert (Sv).

from ICRP Publication 133, 2016

The equivalent dose to a tissue or organ is defined as:

[math] H_T = \displaystyle \sum_{R} w_RD_{R,T} [/math]

where 𝑤𝑅 is the radiation weighting factor for radiation type R, and 𝐷𝑅,𝑇 is the organ absorbed dose from radiation type R in a tissue or organ 𝑟𝑇 of the Reference Adult Male or the Reference Adult Female. As 𝑤𝑅 is dimensionless, the SI unit for the equivalent dose is the same as for absorbed dose, joule per kilogram (J kg-1) and its special name is sievert (Sv).